| Electrical data | CECC 22000 | Requirements | |||||||||||||||||
| Impedance |
50 |
||||||||||||||||||
| Frequency range |
DC ... |
12.4 |
GHz | ||||||||||||||||
|
Typical return loss (mated pair) |
DC - 2.5 GHz 32 dB |
2.5 - 6 GHz 30 dB |
6 - 12.4 GHz 16 dB |
||||||||||||||||
| Dielectric withstanding voltage1) | 4.4.5 |
1 kV |
rms, |
50 Hz | |||||||||||||||
| Working voltage1) | IEC 169-1 11.6.1 |
≤ 330 V |
rms, |
50 Hz | |||||||||||||||
| Insulation resistance | 4.4.4 |
≥ |
1 GΩ | ||||||||||||||||
|
Contact resistance - centre contact - outer contact |
4.4.2 4.4.3 |
|
5 mΩ 1 mΩ |
||||||||||||||||
1) at sea level
| Mechanical data | CECC 22000 | Requirements | |||||||||||||||||
| Engagement force * | 4.5.4 | max. 30 N / max. 6.7 lbs | |||||||||||||||||
| Disengagement force * | 4.5.4 | 8 - 30 N / 1.8- 6.7 lbs | |||||||||||||||||
| Durability (matings) | 4.7.1 | 500 | |||||||||||||||||
* MMBX
| Material data | |||||||||||||||||||
| Connector parts | Material | Plating | |||||||||||||||||
| MMBX centre contact | copper-beryllium alloy | SUCOPRO/gold | |||||||||||||||||
| MMBX outer contact | brass/copper-beryllium | SUCOPRO | |||||||||||||||||
| MMBX body | brass/copper-beryllium | SUCOPRO | |||||||||||||||||
| MMBX insulators | LCP / PTFE / PFA | ||||||||||||||||||
| Environmental data | CECC 22000 | Equivalent mil test conditions | |||||||||||||||||
| Temperature range | -55°C ... +155°C / - 67° F ... + 311° F | ||||||||||||||||||
| Climatic category | → 55 / 155 / 21 | ||||||||||||||||||
| Thermal shock | 4.6.7 → IEC 68-2-14 Na | MIL-STD-202, Method 107 G, Condition B1 | |||||||||||||||||
| Moisture resistance | 4.6.6 → IEC 68-2-3 Ca | MIL-STD-202, Method 106 F | |||||||||||||||||
| Corrosion | 4.6.10 → IEC 68-2-11 Ka | MIL-STD-202, Method 101, Condition B | |||||||||||||||||
| Vibration | 4.6.3 → IEC 68-2-6 Fc | MIL-STD-202, Method 204 D, Condition A | |||||||||||||||||
Some connectors may have a specification that differs from the above mentioned data.