DE
Søg RF produkter
Radio Frequency
RF Cable Assemblies
RF Cables
RF Connectors
RF Railway Connectors
Product Groups
Adaptors
Series / Specifications
1.0/2.3
7/16
BMA
BNC connector 50 Ohm
BNC 75
BNC 75 HDTV
BNO
BNT
C 50 Ω
MCX 50
MCX 75
MHV
MBX
MMBX
Technical data cable connectors
Technical data PCB connectors
Technical data adaptors
Applications
MMCX
MMPX
MXP
N 50
N 75
PC 3.5
QLA 00
QMA
QMA vandtæt
QN
QUICK-FIT
SHV
SK
SMA connector
SMB
SMC
SMPX
SMS
TNC 50
TNC 75
TNCA 50
UHF
Packaging
Quick Lock Formula
Polycon DIN 7/16
Tools
Accessories
Knowledge base
Reverse polarity Connectors
Hermetically sealed connectors
Non-magnetic products
Connectors for SPUMA and LMR cables
RF Antennas
RF Components
Lightning / EMP Protectors
Filter
Couplers
Reactive Splitters
Wilkinson Splitters
RF Power Switch
RF General Info
Fiber Optics
Low Frequency
Product search
Produkter » Radio Frequency » RF Connectors » Product Groups » Series / Specifications » MMBX » Technical data adaptors

Print viewTechnical data of MMBX adaptors

Electrical data CECC 22000 Requirements    
Impedance    

50

 
Frequency range  

DC ...

12.4

GHz
Typical return loss
(mated pair)
  DC - 2.5
GHz
32 dB
2.5 - 6 GHz
30 dB
6 - 12.4 GHz
16 dB
Dielectric withstanding voltage1) 4.4.5

1 kV

rms,

50 Hz
Working voltage1) IEC 169-1 11.6.1

≤ 330 V

rms,

50 Hz
Insulation resistance 4.4.4

1 GΩ  
Contact resistance
- centre contact
- outer contact

4.4.2
4.4.3




5 mΩ
1 mΩ
 

1) at sea level

Mechanical data CECC 22000 Requirements
Engagement force * 4.5.4 max. 30 N / max. 6.7 lbs
Disengagement force * 4.5.4 8 - 30 N / 1.8- 6.7 lbs
Durability (matings) 4.7.1 500

* MMBX

Material data    
Connector parts Material Plating
MMBX centre contact copper-beryllium alloy SUCOPRO/gold
MMBX outer contact brass/copper-beryllium SUCOPRO
MMBX body brass/copper-beryllium SUCOPRO
MMBX insulators LCP / PTFE / PFA  

Environmental data CECC 22000 Equivalent mil test conditions
Temperature range   -55°C ... +155°C / - 67° F ... + 311° F
Climatic category → 55 / 155 / 21  
Thermal shock 4.6.7 → IEC 68-2-14 Na MIL-STD-202, Method 107 G, Condition B1
Moisture resistance 4.6.6 → IEC 68-2-3 Ca MIL-STD-202, Method 106 F
Corrosion 4.6.10 → IEC 68-2-11 Ka MIL-STD-202, Method 101, Condition B
Vibration 4.6.3 → IEC 68-2-6 Fc MIL-STD-202, Method 204 D, Condition A

Some connectors may have a specification that differs from the above mentioned data.

The products are designed and guaranteed to pass the above mentioned test procedures. Any additional or different requirement arising from specific applications or environmental conditions which is not covered by these test procedures is subject to request.

privacy policy | disclaimer © 2012 HUBER+SUHNER | last review 07-Maj-2009